After this chapter you'll be able to see, in real time, how your speakers actually measure in your room. You'll also be able to capture those measurements as snapshots, compare them, and export them. This is the Manual Measurement screen: a free-form tool for looking closely at your system. (For the guided, automatic version that also calculates correction, see Chapter 9 — Room correction & calibration.)

Opening the measurement screen

  1. 1Click Calibrate in the sidebar.
  2. 2On the setup page, choose Manual Measurement (Open →).

You'll see Real-Time Measurement, with the note "Play pink noise and capture the room response." If the app isn't set up yet, it shows Device Setup Required first. Pick your mic and output, then Apply (Chapter 12 — Settings).

Running a measurement

  1. 1Click Start Noise. The app plays pink noise through your selected output and shows the live response. The status pill reads OK — Measuring — playing pink noise.
  2. 2Watch the frequency-response chart fill in.
  3. 3Click Stop Noise when you're done.
Watch out

Pink noise is loud and constant. Set your volume low, then raise it. Don't stand next to a speaker while it plays.

Auto Capture — one-click measurement

If you want a clean capture without watching the chart, click Auto Capture (wand). It does the whole run for you: starts the noise, waits until the measurement is stable, takes a snapshot, then stops the noise. While it waits, the status pill reads Auto Capture — Waiting for a stable measurement with a progress percentage. To cancel, click Stop Noise. No snapshot is taken.

Reading the charts

  • Frequency response (top): level (dB) against frequency (about 25 Hz to 20 kHz, on a log scale). This is the shape of your sound: peaks are too-loud regions, dips are too-quiet ones.
  • Coherence overlay: a coloured trace (red → yellow → green) showing how trustworthy the measurement is at each frequency. Green means reliable. Red means noise, reflections or timing problems are making that part of the measurement unreliable.
  • Phase response (bottom): the timing/phase of the signal, wrapped between +180° and −180°. Where the measurement is too unreliable to give a meaningful phase reading, the line is left blank rather than drawn as noise.

Hover the chart for a readout of Freq, Gain, Phase and Confidence (the coherence at that point, as a percentage).

Tip

Aim for a measurement that's mostly green in the coherence overlay across the range you care about. If it's red everywhere, raise the playback level, quieten the room, and check your mic. A low-confidence measurement will mislead both you and the correction engine.

Live diagnostics below the charts

While you measure, a collapsible Diagnostics panel appears below the charts. It runs the same room analysis as the results page, but live: plain-language cards pointing out reflections, room nulls, resonances and measurement-quality problems as the microphone hears them. Move a speaker or quieten the room and watch the cards update.

  • Hover a card to shade its frequency band on the chart, so you can see exactly where the finding lives.
  • Select a snapshot and the panel describes that capture instead of the live signal (the panel's title shows the snapshot's name).
  • The charts and snapshot list stay pinned at the top while the diagnostics scroll beneath them.

For what each card means and what to do about it, see Chapter 15 — Diagnostics.

Snapshots

A snapshot freezes the current measurement so you can keep it, name it, and compare it against others (for example, left vs. right, or before vs. after moving a speaker).

Capture a snapshot

  1. 1While measuring, click Take Snapshot (camera). (It's greyed out until you start measuring.)
  2. 2The Edit Snapshot Details window opens straight away. Give it a Name, pick a colour, and optionally set the Speaker ID (which output it belongs to). Click Update.

Or let the app do it: Auto Capture (see above) starts the noise, waits for a stable measurement, and takes the snapshot for you.

The Realtime row at the top of the snapshot list is always the live signal. Each captured snapshot below it has:

  • a colour dot: click to show/hide it on the chart;
  • a name: click to select it (click again to deselect);
  • a red ✕: click to delete it.

Work with the selected snapshot

The Selected Snapshot bar shows the current one, with:

  • Edit: rename / recolour / reassign it.
  • Manual offset controls (see below).
  • A Phase group after EQ: how many phase sections the snapshot has, Edit phase and Bypass (see below).
  • Reference: set a snapshot as the reference (Set as Reference) to compare others against it. Remove clears it.

Manual offsets (Delay / Gain / Polarity)

You can nudge a snapshot's timing, level and polarity to see how it would line up, without touching the device:

  • Delay: + / − step by 0.5 ms (hold Shift for a fine 0.025× step), and the ↩︎ button resets to 0.
  • Gain: + / − step by 0.5 dB (Shift for fine), and ↩︎ resets.
  • Polarity: a single button that flips polarity (amber when inverted).

These update the chart instantly. They're a measurement aid, not a device change, until you use Apply to….

Phase sections

A snapshot can also carry phase sections: all-pass filters that rotate phase and leave magnitude unchanged. Align Only can fit them (see Chapter 9 — Room correction & calibration), and you can add or change them yourself. The Phase group in the Selected Snapshot bar shows the section count ("2 sections").

  • Edit phase: opens the phase-rotator editor for the snapshot. It takes up to 6 sections, from 20 Hz to 20 kHz (the top is lower on a snapshot measured at a low sample rate). Choose Save to keep your changes or Cancel to leave them. It is disabled for the realtime trace.
  • Bypass: switches the sections off without deleting them. It is disabled while the snapshot has no sections.

Phase sections draw into the phase trace only. Combine includes them. Room correction from snapshots ignores them, as it ignores EQ offsets, and its tab says so.

Apply a snapshot to an output

Apply to… in the Selected Snapshot bar writes the snapshot's delay, gain, polarity, EQ filters and phase sections to one output: a DSP output or a loopback channel. Pick the output (it starts on the one the snapshot was measured on), then untick any part you want to leave as it is. Each box shows the value it will write.

What you tick replaces the output's own setting. With EQ ticked, the output's EQ and phase alignment are cleared first, then the snapshot's enabled filters are written in order. Bypassed or switched-off filters are not written, so the output plays the curve you see on the chart. The snapshot itself doesn't change.

If the output can't hold everything, the dialog says what will be left out before you confirm: filters past the output's band count are dropped, a Q or frequency outside the output's range is pulled to the nearest value it accepts, and a delay or gain out of range is skipped. Choose Apply anyway to write the rest.

The Phase part writes the snapshot's enabled, unbypassed phase sections to the output's phase-align block. It is unticked and disabled on an output with no such block, and the dialog says "This output has no phase-align block." When the output has fewer slots than the snapshot has sections, the last sections are dropped and the dialog says how many. With EQ ticked and Phase unticked, the dialog warns "Clears this output's existing phase alignment." A snapshot with phase sections also shows a note: the sections were fitted together with the other aligned snapshots, so apply those too. Apply to… never changes phase on other outputs.

The result is listed on the Applied Correction page like a room correction. The home-page Bypass switches it off and back on with the rest; the switch on its card on the Applied Correction page switches it alone. If the output was part of an earlier correction, it moves to this one; the dialog tells you which.

Combine, export and load

The row of buttons under the snapshots:

  • Combine: sum two or more snapshots into one response (Combine Snapshots, pick at least two).
  • Auto Calibration: start room correction (or Align Only) from your snapshots. See Chapter 9 — Room correction & calibration.
  • Export CSV / Export All: with a snapshot selected the button is Export CSV (that one snapshot). With nothing selected it's Export All (one CSV per snapshot into a folder you choose). The CSV carries the snapshot's name, colour, sample rate, latency, offsets and phase sections. See Appendix B — File formats.
  • Load: import one or more snapshot CSVs back in (multi-select).

Measurement settings

Click the gear (Measurement settings) in the toolbar to open the settings panel.

SettingOptionsDefaultWhat it does
AveragingSlow / Fast / Ultra-Fast / FIFO4 – FIFO32SlowHow the live curve settles — see below.
SmoothingNone … 1/1 Oct1/6 OctSmooths the displayed curve. View only — doesn't change data.
CoherenceLow / Medium / High / Very HighLowHides frequencies below this confidence level.
Graph ScaleFull Scale / ±24dB Norm / Custom…Full ScaleThe zoom of the chart — see below.

The panel also holds the Latency Drift Check diagnostic. See Chapter 15 — Diagnostics.

Averaging modes

Averaging controls how the live curve settles. (Stop the noise first: the dropdown is locked while a measurement runs.)

  • Slow / Fast / Ultra-Fast behave like a level meter: the curve continuously eases towards the latest sound, settling over roughly 1.5 s / 500 ms / 250 ms. Slow is the steadiest and the most trustworthy.
  • FIFO4 – FIFO32 average exactly the last 4–32 frames of data. The trace settles in a fixed, predictable time and then stops changing if the room does, which is good for careful before/after comparisons.
Note

Advanced

Fast and Ultra-Fast average so little data that the coherence overlay reads optimistically high. When confidence accuracy matters, use Slow or a FIFO mode.

Custom graph view

Pick Custom… under Graph Scale to set your own window: the Custom Graph View dialog asks for a Scale (the ±dB window), and a From / To frequency range in Hz. Click Save to apply. While Custom is active, an Edit button appears next to the dropdown to reopen the dialog.

Note

Advanced

If your microphone input and speaker output run on different audio interfaces, their clocks drift apart slightly. Omnissiah corrects this automatically, so there is no setting for it.

Tip

Smoothing and Graph Scale only change how the chart looks. They never change the captured measurement or any correction calculated from it.

This manual is licensed to owners of Omnissiah for using the product. It may not be used to build competing software.

Tantrum Audio logo in footer
Tantrum Audio Instagram Share Widget